Technical specifications

Rated voltage230V
Surge current capacity3kA
Built-in depth69mm
Rated fault current0.03A
Width in number of modular spacings2
Pollution degree2
Current limiting class-
Leakage current typeOther
Over voltage category3
Voltage typeAC
Rated insulation voltage Ui-V
Rated current40A
Release characteristicC
Frequency50/60 Hz
Degree of protection (IP)IP2X
Number of protected poles1
Concurrently switching neutral conductorYes
Connectable conductor cross section solid-coremm²
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to IEC 60947-210kA
Anti-nuisance tripping versionNo
Suitable for flush-mounted installationNo
Connectable conductor cross section multi-wiredmm²
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 610096kA
Ambient temperature during operating-25 - 55°C
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR255480R1404 | DS201 C40 APR30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

230V

Surge current capacity

3kA

Built-in depth

69mm

Rated fault current

0.03A

Width in number of modular spacings

2

Pollution degree

2

Current limiting class

-

Leakage current type

Other

Over voltage category

3

Voltage type

AC

Rated insulation voltage Ui

-V

Rated current

40A

Release characteristic

C

Frequency

50/60 Hz

Degree of protection (IP)

IP2X

Number of protected poles

1

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

mm²

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Anti-nuisance tripping version

Suitable for flush-mounted installation

Connectable conductor cross section multi-wired

mm²

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 55°C

Number of poles (total)

2