Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Anti-nuisance tripping versionNo
Rated voltage230V
Number of poles (total)2
Surge current capacity0kA
Power loss2.6W
Degree of protection (IP)IP2X
Release characteristicB
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Leakage current typeAC
Suitable for flush-mounted installationNo
Rated fault current0.1A
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated current6A
Flush-mounted installationNo
Current limiting class-
Connectable conductor cross section solid-coremm²
Connectable conductor cross section multi-wiredmm²
Frequency50/60 Hz
Rated insulation voltage Ui-V
Over voltage category3
Pollution degree2
Concurrently switching neutral conductorYes
With interlocking deviceNo
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275080R2065 | DS201 M B6 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Anti-nuisance tripping version

Rated voltage

230V

Number of poles (total)

2

Surge current capacity

0kA

Power loss

2.6W

Degree of protection (IP)

IP2X

Release characteristic

B

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Leakage current type

AC

Suitable for flush-mounted installation

Rated fault current

0.1A

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated current

6A

Flush-mounted installation

Current limiting class

-

Connectable conductor cross section solid-core

mm²

Connectable conductor cross section multi-wired

mm²

Frequency

50/60 Hz

Rated insulation voltage Ui

-V

Over voltage category

3

Pollution degree

2

Concurrently switching neutral conductor

With interlocking device

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.