Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui-V
Rated current13A
Built-in depth69mm
Rated voltage230V
Release characteristicB
Rated fault current0.1A
Voltage typeAC
Leakage current typeAC
Connectable conductor cross section solid-coremm²
With interlocking deviceNo
Number of poles (total)2
Pollution degree2
Anti-nuisance tripping versionNo
Number of protected poles1
Concurrently switching neutral conductorYes
Current limiting class-
Connectable conductor cross section multi-wiredmm²
Rated short-circuit breaking capacity according to IEC 60947-215kA
Power loss3.5W
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 6100910kA
Suitable for flush-mounted installationNo
Flush-mounted installationNo
Over voltage category3
Degree of protection (IP)IP2X
Surge current capacity0kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Frequency50/60 Hz
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275080R2135 | DS201 M B13 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

-V

Rated current

13A

Built-in depth

69mm

Rated voltage

230V

Release characteristic

B

Rated fault current

0.1A

Voltage type

AC

Leakage current type

AC

Connectable conductor cross section solid-core

mm²

With interlocking device

Number of poles (total)

2

Pollution degree

2

Anti-nuisance tripping version

Number of protected poles

1

Concurrently switching neutral conductor

Current limiting class

-

Connectable conductor cross section multi-wired

mm²

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Power loss

3.5W

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Suitable for flush-mounted installation

Flush-mounted installation

Over voltage category

3

Degree of protection (IP)

IP2X

Surge current capacity

0kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Frequency

50/60 Hz

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.