Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class-
Voltage typeAC
Rated current40A
Leakage current typeAC
Rated voltage230V
Rated fault current0.1A
Rated insulation voltage Ui-V
Built-in depth69mm
Release characteristicB
Surge current capacity0kA
Over voltage category3
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wiredmm²
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
Pollution degree2
Width in number of modular spacings2
Degree of protection (IP)IP2X
With interlocking deviceNo
Power loss9.1W
Number of poles (total)2
Connectable conductor cross section solid-coremm²
Frequency50/60 Hz
Flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 6100910kA
Number of protected poles1
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275080R2405 | DS201 M B40 AC100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

-

Voltage type

AC

Rated current

40A

Leakage current type

AC

Rated voltage

230V

Rated fault current

0.1A

Rated insulation voltage Ui

-V

Built-in depth

69mm

Release characteristic

B

Surge current capacity

0kA

Over voltage category

3

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

mm²

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Pollution degree

2

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

With interlocking device

Power loss

9.1W

Number of poles (total)

2

Connectable conductor cross section solid-core

mm²

Frequency

50/60 Hz

Flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Number of protected poles

1

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.