Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui-V
Width in number of modular spacings2
Voltage typeAC
Release characteristicC
Current limiting class-
Degree of protection (IP)IP2X
Pollution degree2
Rated voltage230V
Built-in depth69mm
Suitable for flush-mounted installationNo
Rated current20A
Rated short-circuit breaking capacity according to IEC 60947-215kA
Concurrently switching neutral conductorYes
Frequency50/60 Hz
Connectable conductor cross section solid-coremm²
Number of protected poles1
Over voltage category3
Leakage current typeAC
Rated fault current0.3A
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Connectable conductor cross section multi-wiredmm²
Surge current capacity0kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Number of poles (total)2
Rated impulse withstand voltage Uimp-kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275080R3204 | DS201 M C20 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated insulation voltage Ui

-V

Width in number of modular spacings

2

Voltage type

AC

Release characteristic

C

Current limiting class

-

Degree of protection (IP)

IP2X

Pollution degree

2

Rated voltage

230V

Built-in depth

69mm

Suitable for flush-mounted installation

Rated current

20A

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Concurrently switching neutral conductor

Frequency

50/60 Hz

Connectable conductor cross section solid-core

mm²

Number of protected poles

1

Over voltage category

3

Leakage current type

AC

Rated fault current

0.3A

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Connectable conductor cross section multi-wired

mm²

Surge current capacity

0kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Number of poles (total)

2

Rated impulse withstand voltage Uimp

-kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.