Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Built-in depth69mm
Release characteristicB
Rated fault current0.3A
Rated insulation voltage Ui-V
Rated voltage230V
Surge current capacity0kA
Leakage current typeAC
Current limiting class-
Over voltage category3
Rated current32A
Power loss9.9W
Pollution degree2
Width in number of modular spacings2
Frequency50/60 Hz
Connectable conductor cross section multi-wiredmm²
Flush-mounted installationNo
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Rated short-circuit breaking capacity according to IEC 60947-215kA
With interlocking deviceNo
Connectable conductor cross section solid-coremm²
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp-kV
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
Number of protected poles1
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275080R3325 | DS201 M B32 AC300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Built-in depth

69mm

Release characteristic

B

Rated fault current

0.3A

Rated insulation voltage Ui

-V

Rated voltage

230V

Surge current capacity

0kA

Leakage current type

AC

Current limiting class

-

Over voltage category

3

Rated current

32A

Power loss

9.9W

Pollution degree

2

Width in number of modular spacings

2

Frequency

50/60 Hz

Connectable conductor cross section multi-wired

mm²

Flush-mounted installation

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

With interlocking device

Connectable conductor cross section solid-core

mm²

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

-kV

Suitable for flush-mounted installation

Anti-nuisance tripping version

Number of protected poles

1

Rated short-circuit breaking capacity according to EN 61009

10kA