Technical specifications

Over voltage category3
Built-in depth69mm
Pollution degree2
Rated insulation voltage Ui-V
Width in number of modular spacings2
Surge current capacity-kA
Current limiting class-
Rated voltage230V
Leakage current typeA
Rated fault current0.03A
Rated current13A
Release characteristicB
Voltage typeAC
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of protected poles1
Power loss3.5W
Concurrently switching neutral conductorYes
Degree of protection (IP)IP2X
Frequency50/60 Hz
Suitable for flush-mounted installationNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Connectable conductor cross section multi-wiredmm²
Ambient temperature during operating-25 - 55°C
Rated impulse withstand voltage Uimp-kV
Connectable conductor cross section solid-coremm²
Flush-mounted installationNo
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
Anti-nuisance tripping versionNo
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R1135 | DS201 M B13 A30

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Over voltage category

3

Built-in depth

69mm

Pollution degree

2

Rated insulation voltage Ui

-V

Width in number of modular spacings

2

Surge current capacity

-kA

Current limiting class

-

Rated voltage

230V

Leakage current type

A

Rated fault current

0.03A

Rated current

13A

Release characteristic

B

Voltage type

AC

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of protected poles

1

Power loss

3.5W

Concurrently switching neutral conductor

Degree of protection (IP)

IP2X

Frequency

50/60 Hz

Suitable for flush-mounted installation

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Connectable conductor cross section multi-wired

mm²

Ambient temperature during operating

-25 .. 55°C

Rated impulse withstand voltage Uimp

-kV

Connectable conductor cross section solid-core

mm²

Flush-mounted installation

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

Anti-nuisance tripping version

Number of poles (total)

2