Aleta.hr
Main Product Image

2CSR275180R1254 | DS201 M C25 A30

Code: 1887186

ManufacturerABB
Catalog number2CSR275180R1254
EAN code8012542569213

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wiredmm²
Connectable conductor cross section solid-coremm²
Rated impulse withstand voltage Uimp-kV
Rated insulation voltage Ui-V
Current limiting class-
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Surge current capacity-kA
Number of poles (total)2
Number of protected poles1
Leakage current typeA
Rated current25A
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated fault current0.03A
Rated voltage230V
Rated short-circuit breaking capacity according to EN 6100910kA
Concurrently switching neutral conductorYes
Voltage typeAC
Frequency50/60 Hz
Release characteristicC
With interlocking deviceNo
Over voltage category3
Pollution degree2
Built-in depth69mm
Width in number of modular spacings2
Degree of protection (IP)IP2X
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Anti-nuisance tripping versionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R1254 | DS201 M C25 A30

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Connectable conductor cross section multi-wired

mm²

Connectable conductor cross section solid-core

mm²

Rated impulse withstand voltage Uimp

-kV

Rated insulation voltage Ui

-V

Current limiting class

-

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Surge current capacity

-kA

Number of poles (total)

2

Number of protected poles

1

Leakage current type

A

Rated current

25A

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated fault current

0.03A

Rated voltage

230V

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

Voltage type

AC

Frequency

50/60 Hz

Release characteristic

C

With interlocking device

Over voltage category

3

Pollution degree

2

Built-in depth

69mm

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Anti-nuisance tripping version