Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current typeA
Rated insulation voltage Ui-V
Rated current6A
Rated fault current0.1A
Rated voltage230V
Surge current capacity-kA
Voltage typeAC
Built-in depth69mm
Release characteristicB
Concurrently switching neutral conductorYes
Frequency50/60 Hz
Pollution degree2
Power loss2.6W
Current limiting class-
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated short-circuit breaking capacity according to IEC 60947-215kA
Width in number of modular spacings2
Degree of protection (IP)IP2X
Flush-mounted installationNo
Over voltage category3
Anti-nuisance tripping versionNo
Connectable conductor cross section multi-wiredmm²
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Connectable conductor cross section solid-coremm²
Ambient temperature during operating-25 - 55°C
Suitable for flush-mounted installationNo
Rated impulse withstand voltage Uimp-kV
Number of poles (total)2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R2065 | DS201 M B6 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Leakage current type

A

Rated insulation voltage Ui

-V

Rated current

6A

Rated fault current

0.1A

Rated voltage

230V

Surge current capacity

-kA

Voltage type

AC

Built-in depth

69mm

Release characteristic

B

Concurrently switching neutral conductor

Frequency

50/60 Hz

Pollution degree

2

Power loss

2.6W

Current limiting class

-

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Width in number of modular spacings

2

Degree of protection (IP)

IP2X

Flush-mounted installation

Over voltage category

3

Anti-nuisance tripping version

Connectable conductor cross section multi-wired

mm²

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Connectable conductor cross section solid-core

mm²

Ambient temperature during operating

-25 .. 55°C

Suitable for flush-mounted installation

Rated impulse withstand voltage Uimp

-kV

Number of poles (total)

2

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.