Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current20A
Release characteristicC
Rated voltage230V
Voltage typeAC
Built-in depth69mm
Leakage current typeA
Frequency50/60 Hz
Suitable for flush-mounted installationNo
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Rated insulation voltage Ui-V
Rated short-circuit breaking capacity according to IEC 60947-215kA
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Surge current capacity-kA
Number of poles (total)2
With interlocking deviceNo
Over voltage category3
Connectable conductor cross section solid-coremm²
Current limiting class-
Power loss5.7W
Width in number of modular spacings2
Anti-nuisance tripping versionNo
Pollution degree2
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Connectable conductor cross section multi-wiredmm²
Rated impulse withstand voltage Uimp-kV
Rated fault current0.1A
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R2204 | DS201 M C20 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Rated current

20A

Release characteristic

C

Rated voltage

230V

Voltage type

AC

Built-in depth

69mm

Leakage current type

A

Frequency

50/60 Hz

Suitable for flush-mounted installation

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Rated insulation voltage Ui

-V

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Surge current capacity

-kA

Number of poles (total)

2

With interlocking device

Over voltage category

3

Connectable conductor cross section solid-core

mm²

Current limiting class

-

Power loss

5.7W

Width in number of modular spacings

2

Anti-nuisance tripping version

Pollution degree

2

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Connectable conductor cross section multi-wired

mm²

Rated impulse withstand voltage Uimp

-kV

Rated fault current

0.1A

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.