Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth69mm
Voltage typeAC
Rated voltage230V
Rated current32A
Suitable for flush-mounted installationNo
Rated insulation voltage Ui-V
Leakage current typeA
Number of protected poles1
Degree of protection (IP)IP2X
Over voltage category3
Release characteristicC
Rated fault current0.1A
Pollution degree2
Width in number of modular spacings2
Frequency50/60 Hz
Rated short-circuit breaking capacity according to IEC 60947-215kA
Concurrently switching neutral conductorYes
Power loss9.9W
Current limiting class-
Flush-mounted installationNo
Number of poles (total)2
Surge current capacity-kA
Connectable conductor cross section solid-coremm²
With interlocking deviceNo
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Rated impulse withstand voltage Uimp-kV
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section multi-wiredmm²
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R2324 | DS201 M C32 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Built-in depth

69mm

Voltage type

AC

Rated voltage

230V

Rated current

32A

Suitable for flush-mounted installation

Rated insulation voltage Ui

-V

Leakage current type

A

Number of protected poles

1

Degree of protection (IP)

IP2X

Over voltage category

3

Release characteristic

C

Rated fault current

0.1A

Pollution degree

2

Width in number of modular spacings

2

Frequency

50/60 Hz

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Concurrently switching neutral conductor

Power loss

9.9W

Current limiting class

-

Flush-mounted installation

Number of poles (total)

2

Surge current capacity

-kA

Connectable conductor cross section solid-core

mm²

With interlocking device

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Rated impulse withstand voltage Uimp

-kV

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section multi-wired

mm²

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.