Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Pollution degree2
Rated insulation voltage Ui-V
Rated fault current0.1A
Suitable for flush-mounted installationNo
Concurrently switching neutral conductorYes
Width in number of modular spacings2
Rated voltage230V
Current limiting class-
Over voltage category3
Surge current capacity-kA
Connectable conductor cross section multi-wiredmm²
Power loss9.1W
With interlocking deviceNo
Rated current40A
Degree of protection (IP)IP2X
Voltage typeAC
Number of protected poles1
Built-in depth69mm
Rated short-circuit breaking capacity according to IEC 60947-215kA
Frequency50/60 Hz
Connectable conductor cross section solid-coremm²
Leakage current typeA
Release characteristicB
Ambient temperature during operating-25 - 55°C
Flush-mounted installationNo
Number of poles (total)2
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 6100910kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R2405 | DS201 M B40 A100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Pollution degree

2

Rated insulation voltage Ui

-V

Rated fault current

0.1A

Suitable for flush-mounted installation

Concurrently switching neutral conductor

Width in number of modular spacings

2

Rated voltage

230V

Current limiting class

-

Over voltage category

3

Surge current capacity

-kA

Connectable conductor cross section multi-wired

mm²

Power loss

9.1W

With interlocking device

Rated current

40A

Degree of protection (IP)

IP2X

Voltage type

AC

Number of protected poles

1

Built-in depth

69mm

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Frequency

50/60 Hz

Connectable conductor cross section solid-core

mm²

Leakage current type

A

Release characteristic

B

Ambient temperature during operating

-25 .. 55°C

Flush-mounted installation

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

10kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.