  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class-
Rated voltage230V
Leakage current typeA
Built-in depth69mm
Over voltage category3
Rated current10A
Voltage typeAC
Rated fault current0.3A
Surge current capacity-kA
Release characteristicB
Rated insulation voltage Ui-V
Frequency50/60 Hz
Flush-mounted installationNo
Connectable conductor cross section solid-coremm²
Width in number of modular spacings2
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to EN 6100910kA
With interlocking deviceNo
Number of poles (total)2
Degree of protection (IP)IP2X
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to IEC 60947-215kA
Ambient temperature during operating-25 - 55°C
Power loss2.3W
Connectable conductor cross section multi-wiredmm²
Concurrently switching neutral conductorYes
Number of protected poles1
Suitable for flush-mounted installationNo
Pollution degree2
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R3105 | DS201 M B10 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Current limiting class

-

Rated voltage

230V

Leakage current type

A

Built-in depth

69mm

Over voltage category

3

Rated current

10A

Voltage type

AC

Rated fault current

0.3A

Surge current capacity

-kA

Release characteristic

B

Rated insulation voltage Ui

-V

Frequency

50/60 Hz

Flush-mounted installation

Connectable conductor cross section solid-core

mm²

Width in number of modular spacings

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to EN 61009

10kA

With interlocking device

Number of poles (total)

2

Degree of protection (IP)

IP2X

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Ambient temperature during operating

-25 .. 55°C

Power loss

2.3W

Connectable conductor cross section multi-wired

mm²

Concurrently switching neutral conductor

Number of protected poles

1

Suitable for flush-mounted installation

Pollution degree

2