Technical specifications

Voltage typeAC
Rated voltage230V
Release characteristicC
Rated insulation voltage Ui-V
Built-in depth69mm
Leakage current typeA
Width in number of modular spacings2
Surge current capacity-kA
Over voltage category3
Current limiting class-
Pollution degree2
Degree of protection (IP)IP2X
Rated short-circuit breaking capacity according to IEC 60947-215kA
Suitable for flush-mounted installationNo
Connectable conductor cross section solid-coremm²
Frequency50/60 Hz
Connectable conductor cross section multi-wiredmm²
Anti-nuisance tripping versionNo
Ambient temperature during operating-25 - 55°C
With interlocking deviceNo
Rated impulse withstand voltage Uimp-kV
Rated short-circuit breaking capacity according to EN 6100910kA
Rated fault current0.3A
Number of poles (total)2
Rated current16A
Number of protected poles1
Rated short-circuit breaking capacity Icn according to EN 61009-110kA
Concurrently switching neutral conductorYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R3164 | DS201 M C16 A300

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

230V

Release characteristic

C

Rated insulation voltage Ui

-V

Built-in depth

69mm

Leakage current type

A

Width in number of modular spacings

2

Surge current capacity

-kA

Over voltage category

3

Current limiting class

-

Pollution degree

2

Degree of protection (IP)

IP2X

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Suitable for flush-mounted installation

Connectable conductor cross section solid-core

mm²

Frequency

50/60 Hz

Connectable conductor cross section multi-wired

mm²

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 55°C

With interlocking device

Rated impulse withstand voltage Uimp

-kV

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated fault current

0.3A

Number of poles (total)

2

Rated current

16A

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Concurrently switching neutral conductor

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.