Aleta.hr
Main Product Image

2CSR275180R3205 | DS201 M B20 A300

Code: 1887216

ManufacturerABB
Catalog number2CSR275180R3205
EAN code8012542770916

















Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)IP2X
Voltage typeAC
Built-in depth69mm
Suitable for flush-mounted installationNo
Rated current20A
Rated voltage230V
Width in number of modular spacings2
Ambient temperature during operating-25 - 55°C
Release characteristicB
Connectable conductor cross section multi-wiredmm²
Number of protected poles1
Connectable conductor cross section solid-coremm²
Over voltage category3
Rated impulse withstand voltage Uimp-kV
Rated insulation voltage Ui-V
Number of poles (total)2
Current limiting class-
Pollution degree2
Concurrently switching neutral conductorYes
Frequency50/60 Hz
Leakage current typeA
With interlocking deviceNo
Rated fault current0.3A
Anti-nuisance tripping versionNo
Rated short-circuit breaking capacity according to IEC 60947-215kA
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Power loss5.7W
Surge current capacity-kA
Flush-mounted installationNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275180R3205 | DS201 M B20 A300

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Degree of protection (IP)

IP2X

Voltage type

AC

Built-in depth

69mm

Suitable for flush-mounted installation

Rated current

20A

Rated voltage

230V

Width in number of modular spacings

2

Ambient temperature during operating

-25 .. 55°C

Release characteristic

B

Connectable conductor cross section multi-wired

mm²

Number of protected poles

1

Connectable conductor cross section solid-core

mm²

Over voltage category

3

Rated impulse withstand voltage Uimp

-kV

Rated insulation voltage Ui

-V

Number of poles (total)

2

Current limiting class

-

Pollution degree

2

Concurrently switching neutral conductor

Frequency

50/60 Hz

Leakage current type

A

With interlocking device

Rated fault current

0.3A

Anti-nuisance tripping version

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Power loss

5.7W

Surge current capacity

-kA

Flush-mounted installation

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.