Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage typeAC
Rated voltage230V
Release characteristicC
Built-in depth69mm
Rated insulation voltage Ui-V
Rated current32A
Rated fault current0.1A
Leakage current typeOther
Suitable for flush-mounted installationNo
Current limiting class-
Pollution degree2
Rated short-circuit breaking capacity according to IEC 60947-215kA
Frequency50/60 Hz
Number of poles (total)2
Connectable conductor cross section multi-wiredmm²
Degree of protection (IP)IP2X
Concurrently switching neutral conductorYes
Number of protected poles1
Over voltage category3
Power loss9.9W
Flush-mounted installationNo
Ambient temperature during operating-25 - 55°C
Connectable conductor cross section solid-coremm²
Width in number of modular spacings2
Surge current capacity3kA
With interlocking deviceNo
Rated short-circuit breaking capacity according to EN 6100910kA
Rated short-circuit breaking capacity Icn according to EN 61009-1-kA
Anti-nuisance tripping versionNo
Rated impulse withstand voltage Uimp-kV
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

2CSR275480R2324 | DS201 M C32 APR100

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • ABB

Technical specifications

Voltage type

AC

Rated voltage

230V

Release characteristic

C

Built-in depth

69mm

Rated insulation voltage Ui

-V

Rated current

32A

Rated fault current

0.1A

Leakage current type

Other

Suitable for flush-mounted installation

Current limiting class

-

Pollution degree

2

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Frequency

50/60 Hz

Number of poles (total)

2

Connectable conductor cross section multi-wired

mm²

Degree of protection (IP)

IP2X

Concurrently switching neutral conductor

Number of protected poles

1

Over voltage category

3

Power loss

9.9W

Flush-mounted installation

Ambient temperature during operating

-25 .. 55°C

Connectable conductor cross section solid-core

mm²

Width in number of modular spacings

2

Surge current capacity

3kA

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

-kA

Anti-nuisance tripping version

Rated impulse withstand voltage Uimp

-kV

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.