Aleta.hr

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Number of analogue inputs1
Number of analogue outputs0
Height239mm
With control elementYes
Width70mm
Supporting protocol for LONNo
Number of digital outputs0
Number of digital inputs5
Depth142mm
Number of HW-interfaces industrial Ethernet0
Number of HW-interfaces RS-4850
Number of HW-interfaces RS-2320
Supporting protocol for Data-HighwayNo
Number of HW-interfaces RS-4220
Supporting protocol for TCP/IPNo
With optical interfaceNo
Number of HW-interfaces parallel0
Supporting protocol for ASINo
Number of HW-interfaces USB0
Supporting protocol for DeviceNetNo
Supporting protocol for KNXNo
Supporting protocol for PROFIBUSNo
Number of HW-interfaces other1
Supporting protocol for INTERBUSNo
Number of HW-interfaces serial TTY0
Supporting protocol for CANNo
Supporting protocol for ModbusNo
Supporting protocol for SERCOSNo
With PC connectionYes
Supporting protocol for other bus systemsNo
Mains voltage380 - 480V
Supporting protocol for INTERBUS-SafetyNo
Degree of protection (IP)IP20
Supporting protocol for SUCONETNo
Number of phases input3
Type of converterU converter
Integrated breaking resistanceNo
Mains frequency50/60 Hz
Application in industrial area permittedYes
Number of interfaces PROFINET0
Application in domestic- and commercial area permittedNo
Max. output at quadratic load at rated output voltage1.1kW
Max. output at linear load at rated output voltage1.1kW
Relative symmetric net voltage tolerance10%
Max. output frequency500Hz
4-quadrant operation possibleNo
Number of phases output3
Supporting protocol for SafetyBUS pNo
Supporting protocol for PROFIsafeNo
Supporting protocol for PROFINET IONo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for Foundation FieldbusNo
Max. output voltage480V
Supporting protocol for EtherNet/IPNo
Supporting protocol for BACnetNo
Supporting protocol for AS-Interface Safety at WorkNo
Nominal output current I2N3.3A
Relative symmetric net frequency tolerance5%
Supporting protocol for PROFINET CBANo
Degree of protection (NEMA)Other

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ACS150-03E-03A3-4 | ACS150-03E-03A3-4

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

Number of analogue inputs

1

Number of analogue outputs

0

Height

239mm

With control element

Width

70mm

Supporting protocol for LON

Number of digital outputs

0

Number of digital inputs

5

Depth

142mm

Number of HW-interfaces industrial Ethernet

0

Number of HW-interfaces RS-485

0

Number of HW-interfaces RS-232

0

Supporting protocol for Data-Highway

Number of HW-interfaces RS-422

0

Supporting protocol for TCP/IP

With optical interface

Number of HW-interfaces parallel

0

Supporting protocol for ASI

Number of HW-interfaces USB

0

Supporting protocol for DeviceNet

Supporting protocol for KNX

Supporting protocol for PROFIBUS

Number of HW-interfaces other

1

Supporting protocol for INTERBUS

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for Modbus

Supporting protocol for SERCOS

With PC connection

Supporting protocol for other bus systems

Mains voltage

380 .. 480V

Supporting protocol for INTERBUS-Safety

Degree of protection (IP)

IP20

Supporting protocol for SUCONET

Number of phases input

3

Type of converter

U converter

Integrated breaking resistance

Mains frequency

50/60 Hz

Application in industrial area permitted

Number of interfaces PROFINET

0

Application in domestic- and commercial area permitted

Max. output at quadratic load at rated output voltage

1.1kW

Max. output at linear load at rated output voltage

1.1kW

Relative symmetric net voltage tolerance

10%

Max. output frequency

500Hz

4-quadrant operation possible

Number of phases output

3

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for PROFINET IO

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Max. output voltage

480V

Supporting protocol for EtherNet/IP

Supporting protocol for BACnet

Supporting protocol for AS-Interface Safety at Work

Nominal output current I2N

3.3A

Relative symmetric net frequency tolerance

5%

Supporting protocol for PROFINET CBA

Degree of protection (NEMA)

Other

From same serie

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.