  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

With control elementNo
Number of analogue inputs2
Number of digital outputs3
Width125mm
Number of digital inputs6
Depth223mm
Height373mm
Number of HW-interfaces industrial Ethernet0
Supporting protocol for LONNo
Number of HW-interfaces RS-2320
Number of analogue outputs2
Number of HW-interfaces serial TTY0
Supporting protocol for CANYes
Supporting protocol for TCP/IPYes
Supporting protocol for ModbusYes
Number of HW-interfaces USB1
Supporting protocol for PROFIBUSYes
Number of HW-interfaces parallel2
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for INTERBUSNo
Number of HW-interfaces RS-4851
With optical interfaceNo
Number of HW-interfaces other2
Number of HW-interfaces RS-4220
Supporting protocol for DeviceNetYes
Supporting protocol for Data-HighwayNo
Supporting protocol for SUCONETNo
4-quadrant operation possibleNo
Degree of protection (IP)IP21
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for SERCOSNo
Mains frequency50/60 Hz
With PC connectionNo
Mains voltage380 - 480V
Supporting protocol for other bus systemsYes
Number of interfaces PROFINET0
Integrated breaking resistanceNo
Type of converterU converter
Max. output frequency500Hz
Max. output at quadratic load at rated output voltage2.2kW
Supporting protocol for DeviceNet SafetyYes
Supporting protocol for Foundation FieldbusNo
Number of phases input3
Application in industrial area permittedYes
Relative symmetric net frequency tolerance5%
Relative symmetric net voltage tolerance10%
Supporting protocol for AS-Interface Safety at WorkNo
Application in domestic- and commercial area permittedYes
Max. output at linear load at rated output voltage2.2kW
Supporting protocol for EtherNet/IPYes
Number of phases output3
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IOYes
Supporting protocol for BACnetNo
Supporting protocol for SafetyBUS pNo
Degree of protection (NEMA)1
Max. output voltage480V
Nominal output current I2N5.6A
Supporting protocol for PROFIsafeNo

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

ACS580-01-05A7-4 +J400 | ACS580-01-05A7-4 +J400

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Frequency converter =< 1 kV
  • 1 KOM
  • ABB

Technical specifications

With control element

Number of analogue inputs

2

Number of digital outputs

3

Width

125mm

Number of digital inputs

6

Depth

223mm

Height

373mm

Number of HW-interfaces industrial Ethernet

0

Supporting protocol for LON

Number of HW-interfaces RS-232

0

Number of analogue outputs

2

Number of HW-interfaces serial TTY

0

Supporting protocol for CAN

Supporting protocol for TCP/IP

Supporting protocol for Modbus

Number of HW-interfaces USB

1

Supporting protocol for PROFIBUS

Number of HW-interfaces parallel

2

Supporting protocol for ASI

Supporting protocol for KNX

Supporting protocol for INTERBUS

Number of HW-interfaces RS-485

1

With optical interface

Number of HW-interfaces other

2

Number of HW-interfaces RS-422

0

Supporting protocol for DeviceNet

Supporting protocol for Data-Highway

Supporting protocol for SUCONET

4-quadrant operation possible

Degree of protection (IP)

IP21

Supporting protocol for INTERBUS-Safety

Supporting protocol for SERCOS

Mains frequency

50/60 Hz

With PC connection

Mains voltage

380 .. 480V

Supporting protocol for other bus systems

Number of interfaces PROFINET

0

Integrated breaking resistance

Type of converter

U converter

Max. output frequency

500Hz

Max. output at quadratic load at rated output voltage

2.2kW

Supporting protocol for DeviceNet Safety

Supporting protocol for Foundation Fieldbus

Number of phases input

3

Application in industrial area permitted

Relative symmetric net frequency tolerance

5%

Relative symmetric net voltage tolerance

10%

Supporting protocol for AS-Interface Safety at Work

Application in domestic- and commercial area permitted

Max. output at linear load at rated output voltage

2.2kW

Supporting protocol for EtherNet/IP

Number of phases output

3

Supporting protocol for PROFINET CBA

Supporting protocol for PROFINET IO

Supporting protocol for BACnet

Supporting protocol for SafetyBUS p

Degree of protection (NEMA)

1

Max. output voltage

480V

Nominal output current I2N

5.6A

Supporting protocol for PROFIsafe