Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Adjustment range undelayed short-circuit release1500 - 3250A
Rated permanent current Iu400A
Type of control elementToggle
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Rated voltage220 - 690V
Motor drive optionalYes
Motor drive integratedNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
Overload release current setting100.0 - 250A
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100370R1 | XT5N 400 Ekip M Dip LIU In=250A 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Adjustment range undelayed short-circuit release

1500 .. 3250A

Rated permanent current Iu

400A

Type of control element

Toggle

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Rated voltage

220 .. 690V

Motor drive optional

Motor drive integrated

Position of connection for main current circuit

Front side

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

100.0 .. 250A

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Degree of protection (IP)

IP20

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.