Aleta.hr
Main Product Image

1SDA100396R1 | XT5N 400 Ekip Dip LS/I In=400 4p F F

Code: 1893263

ManufacturerABB
Catalog number1SDA100396R1
EAN code8056221004732

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Adjustment range short-term delayed short-circuit release400 - 4000A
Adjustment range undelayed short-circuit release400 - 4000A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Integrated earth fault protectionNo
Rated permanent current Iu400A
Degree of protection (IP)IP20
With integrated under voltage releaseNo
Motor drive integratedNo
With switched-off indicatorNo
Overload release current setting160.0 - 400A
Motor drive optionalYes
Type of control elementToggle
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100396R1 | XT5N 400 Ekip Dip LS/I In=400 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Adjustment range short-term delayed short-circuit release

400 .. 4000A

Adjustment range undelayed short-circuit release

400 .. 4000A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Integrated earth fault protection

Rated permanent current Iu

400A

Degree of protection (IP)

IP20

With integrated under voltage release

Motor drive integrated

With switched-off indicator

Overload release current setting

160.0 .. 400A

Motor drive optional

Type of control element

Toggle

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.