Aleta.hr
Main Product Image

1SDA100401R1 | XT5N 630 Ekip Dip LSI In=630 4p F F

Code: 1893268

ManufacturerABB
Catalog number1SDA100401R1
EAN code8056221004787

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu630A
Overload release current setting252.0 - 630A
Device constructionBuilt-in device fixed built-in technique
Complete device with protection unitYes
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Motor drive optionalYes
Adjustment range short-term delayed short-circuit release630 - 6300A
Integrated earth fault protectionNo
With integrated under voltage releaseNo
Motor drive integratedNo
With switched-off indicatorNo
Degree of protection (IP)IP20
Type of control elementToggle
Position of connection for main current circuitFront side
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release630 - 6300A
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100401R1 | XT5N 630 Ekip Dip LSI In=630 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

630A

Overload release current setting

252.0 .. 630A

Device construction

Built-in device fixed built-in technique

Complete device with protection unit

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Motor drive optional

Adjustment range short-term delayed short-circuit release

630 .. 6300A

Integrated earth fault protection

With integrated under voltage release

Motor drive integrated

With switched-off indicator

Degree of protection (IP)

IP20

Type of control element

Toggle

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

630 .. 6300A

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.