Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
Overload release current setting128.0 - 320A
Rated permanent current Iu400A
Adjustment range undelayed short-circuit release1920 - 4160A
Integrated earth fault protectionNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Device constructionBuilt-in device fixed built-in technique
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Type of control elementToggle
Degree of protection (IP)IP20
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100441R1 | XT5S 400 Ekip M Dip LIU In=320A 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

Overload release current setting

128.0 .. 320A

Rated permanent current Iu

400A

Adjustment range undelayed short-circuit release

1920 .. 4160A

Integrated earth fault protection

With switched-off indicator

Position of connection for main current circuit

Front side

Device construction

Built-in device fixed built-in technique

With integrated under voltage release

Complete device with protection unit

Motor drive integrated

Motor drive optional

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

Degree of protection (IP)

IP20

Type of electrical connection of main circuit

Bolt connection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.