Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Overload release current setting160.0 - 400A
Rated permanent current Iu400A
Number of auxiliary contacts as normally closed contact0
Number of poles3
Number of auxiliary contacts as normally open contact0
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
With switched-off indicatorNo
Adjustment range undelayed short-circuit release400 - 4000A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100450R1 | XT5S 400 Ekip Dip LIG In=400 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Overload release current setting

160.0 .. 400A

Rated permanent current Iu

400A

Number of auxiliary contacts as normally closed contact

0

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

With switched-off indicator

Adjustment range undelayed short-circuit release

400 .. 4000A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.