Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Integrated earth fault protectionNo
Rated permanent current Iu630A
Rated voltage220 - 690V
Overload release current setting350.0 - 500A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release2500 - 5000A
With integrated under voltage releaseNo
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Motor drive integratedNo
Degree of protection (IP)IP20
Type of control elementToggle
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100457R1 | XT5S 630 TMA 500-5000 4p F F InN=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Integrated earth fault protection

Rated permanent current Iu

630A

Rated voltage

220 .. 690V

Overload release current setting

350.0 .. 500A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

2500 .. 5000A

With integrated under voltage release

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP20

Type of control element

Toggle

Motor drive optional

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.