Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuitFront side
Number of poles4
With integrated under voltage releaseNo
Rated voltage220 - 690V
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Overload release current setting350.0 - 500A
Rated permanent current Iu630A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
Type of control elementToggle
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Motor drive integratedNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range undelayed short-circuit release2500 - 5000A
Complete device with protection unitYes
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100457R1 | XT5S 630 TMA 500-5000 4p F F InN=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Position of connection for main current circuit

Front side

Number of poles

4

With integrated under voltage release

Rated voltage

220 .. 690V

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Overload release current setting

350.0 .. 500A

Rated permanent current Iu

630A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

Type of control element

Toggle

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Motor drive integrated

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range undelayed short-circuit release

2500 .. 5000A

Complete device with protection unit

Type of electrical connection of main circuit

Bolt connection

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.