Aleta.hr
Main Product Image

1SDA100485R1 | XT5H 400 TMA 400-4000 3p F F

Code: 1893344

ManufacturerABB
Catalog number1SDA100485R1
EAN code8056221005623

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Integrated earth fault protectionNo
With switched-off indicatorNo
Adjustment range undelayed short-circuit release2000 - 4000A
Rated permanent current Iu400A
Device constructionBuilt-in device fixed built-in technique
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Overload release current setting280.0 - 400A
DIN rail (top hat rail) mounting optionalYes
Type of control elementToggle
Motor drive integratedNo
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100485R1 | XT5H 400 TMA 400-4000 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Integrated earth fault protection

With switched-off indicator

Adjustment range undelayed short-circuit release

2000 .. 4000A

Rated permanent current Iu

400A

Device construction

Built-in device fixed built-in technique

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

280.0 .. 400A

DIN rail (top hat rail) mounting optional

Type of control element

Toggle

Motor drive integrated

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.