Aleta.hr
Main Product Image

1SDA100516R1 | XT5H 400 Ekip Dip LIG In=400 3p F F

Code: 1893375

ManufacturerABB
Catalog number1SDA100516R1
EAN code8015644010270

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu400A
Adjustment range undelayed short-circuit release400 - 4000A
Overload release current setting160.0 - 400A
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Rated voltage220 - 690V
With switched-off indicatorNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Complete device with protection unitYes
Type of control elementToggle
Motor drive optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100516R1 | XT5H 400 Ekip Dip LIG In=400 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

400A

Adjustment range undelayed short-circuit release

400 .. 4000A

Overload release current setting

160.0 .. 400A

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Rated voltage

220 .. 690V

With switched-off indicator

With integrated under voltage release

Position of connection for main current circuit

Front side

Complete device with protection unit

Type of control element

Toggle

Motor drive optional

Motor drive integrated

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.