Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu400A
Number of auxiliary contacts as normally closed contact0
With integrated under voltage releaseNo
Number of poles4
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Degree of protection (IP)IP20
Type of control elementToggle
Overload release current setting224.0 - 320A
Rated voltage220 - 690V
Position of connection for main current circuitFront side
Type of electrical connection of main circuitBolt connection
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Motor drive optionalYes
Adjustment range undelayed short-circuit release1600 - 3200A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100519R1 | XT5H 400 TMA 320-3200 4p F F InN=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

400A

Number of auxiliary contacts as normally closed contact

0

With integrated under voltage release

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Degree of protection (IP)

IP20

Type of control element

Toggle

Overload release current setting

224.0 .. 320A

Rated voltage

220 .. 690V

Position of connection for main current circuit

Front side

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Motor drive optional

Adjustment range undelayed short-circuit release

1600 .. 3200A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

With switched-off indicator

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

- .. -A

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.