Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Type of electrical connection of main circuitBolt connection
With switched-off indicatorNo
Degree of protection (IP)IP20
Type of control elementToggle
Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of poles4
Motor drive integratedNo
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu630A
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Overload release current setting441.0 - 630A
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release- - -A
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release3150 - 6300A
Integrated earth fault protectionNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100525R1 | XT5H 630 TMA 630-6300 4p F F InN=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Type of electrical connection of main circuit

Bolt connection

With switched-off indicator

Degree of protection (IP)

IP20

Type of control element

Toggle

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of poles

4

Motor drive integrated

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

630A

With integrated under voltage release

Position of connection for main current circuit

Front side

Overload release current setting

441.0 .. 630A

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

- .. -A

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

3150 .. 6300A

Integrated earth fault protection

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.