  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage220 - 690V
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally open contact0
Number of poles4
Adjustment range short-term delayed short-circuit release- - -A
With switched-off indicatorNo
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release448.0 - 1600A
Motor drive integratedNo
Position of connection for main current circuitFront side
Overload release current setting224.0 - 320A
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu400A
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100538R1 | XT5H 400 TMG 320-1600 4p F F In=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

With integrated under voltage release

Degree of protection (IP)

IP20

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Adjustment range short-term delayed short-circuit release

- .. -A

With switched-off indicator

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

448.0 .. 1600A

Motor drive integrated

Position of connection for main current circuit

Front side

Overload release current setting

224.0 .. 320A

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

400A

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.