Number of poles3
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range short-term delayed short-circuit release- - -A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact0
Adjustment range undelayed short-circuit release4800 - 10400A
Rated voltage220 - 690V
Rated permanent current Iu800A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Integrated earth fault protectionNo
Overload release current setting320.0 - 800A
With switched-off indicatorNo
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Complete device with protection unitYes
Motor drive optionalYes
Type of control elementToggle
Degree of protection (IP)IP20
Motor drive integratedNo
Type of electrical connection of main circuitBolt connection
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100727R1 | XT6N 800 Ekip M Dip LIU In=800A 3p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of poles

3

Suitable for DIN rail (top hat rail) mounting

Adjustment range short-term delayed short-circuit release

- .. -A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

0

Adjustment range undelayed short-circuit release

4800 .. 10400A

Rated voltage

220 .. 690V

Rated permanent current Iu

800A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Integrated earth fault protection

Overload release current setting

320.0 .. 800A

With switched-off indicator

Position of connection for main current circuit

Front side

With integrated under voltage release

Complete device with protection unit

Motor drive optional

Type of control element

Toggle

Degree of protection (IP)

IP20

Motor drive integrated

Type of electrical connection of main circuit

Bolt connection