Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Motor drive integratedNo
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz-kA
Adjustment range short-term delayed short-circuit release- - -A
Type of control elementToggle
Rated voltage220 - 690V
Number of poles4
Rated permanent current Iu800A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Adjustment range undelayed short-circuit release4000 - 8000A
Overload release current setting560.0 - 800A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100775R1 | XT6H 800 TMA 800-8000 4p F F InN=100%In

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Motor drive integrated

Position of connection for main current circuit

Front side

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

-kA

Adjustment range short-term delayed short-circuit release

- .. -A

Type of control element

Toggle

Rated voltage

220 .. 690V

Number of poles

4

Rated permanent current Iu

800A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Adjustment range undelayed short-circuit release

4000 .. 8000A

Overload release current setting

560.0 .. 800A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Motor drive optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.