Aleta.hr
Main Product Image

1SDA100835R1 | XT7S 1000 Ekip Dip LSIG In=1000A 3p F F

Code: 1893688

ManufacturerABB
Catalog number1SDA100835R1
EAN code8056221008891

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
With switched-off indicatorNo
Type of control elementToggle
Number of auxiliary contacts as normally closed contact0
Complete device with protection unitYes
Number of auxiliary contacts as change-over contact0
Number of poles3
Overload release current setting400.0 - 1000A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionYes
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release1000 - 10000A
Rated voltage220 - 690V
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release1000 - 10000A
DIN rail (top hat rail) mounting optionalYes
Position of connection for main current circuitFront side
With integrated under voltage releaseNo
Motor drive integratedNo
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100835R1 | XT7S 1000 Ekip Dip LSIG In=1000A 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

With switched-off indicator

Type of control element

Toggle

Number of auxiliary contacts as normally closed contact

0

Complete device with protection unit

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Overload release current setting

400.0 .. 1000A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

1000 .. 10000A

Rated voltage

220 .. 690V

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

1000 .. 10000A

DIN rail (top hat rail) mounting optional

Position of connection for main current circuit

Front side

With integrated under voltage release

Motor drive integrated

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.