Aleta.hr
Main Product Image

1SDA100868R1 | XT7S 1250 Ekip M Touch LRIU In1250 3p FF

Code: 1893721

ManufacturerABB
Catalog number1SDA100868R1
EAN code8056221009225

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
Rated voltage220 - 690V
Overload release current setting500.0 - 1250A
Integrated earth fault protectionNo
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1875.0 - 18750A
Suitable for DIN rail (top hat rail) mountingNo
Rated permanent current Iu1250A
Complete device with protection unitYes
Number of poles3
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
With switched-off indicatorNo
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Degree of protection (IP)IP20
Motor drive optionalYes
Type of control elementToggle
Motor drive integratedNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100868R1 | XT7S 1250 Ekip M Touch LRIU In1250 3p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

Rated voltage

220 .. 690V

Overload release current setting

500.0 .. 1250A

Integrated earth fault protection

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Suitable for DIN rail (top hat rail) mounting

Rated permanent current Iu

1250A

Complete device with protection unit

Number of poles

3

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

With switched-off indicator

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Degree of protection (IP)

IP20

Motor drive optional

Type of control element

Toggle

Motor drive integrated

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.