  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Rated voltage220 - 690V
Overload release current setting400.0 - 1000A
Adjustment range undelayed short-circuit release1500.0 - 15000A
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
Type of electrical connection of main circuitBolt connection
DIN rail (top hat rail) mounting optionalYes
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Number of poles3
Number of auxiliary contacts as normally open contact0
Type of control elementToggle
With integrated under voltage releaseNo
Complete device with protection unitYes
Position of connection for main current circuitFront side
Degree of protection (IP)IP20
Motor drive integratedNo
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100903R1 | XT7H 1000 Ekip Touch LSI In=1000A 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Rated voltage

220 .. 690V

Overload release current setting

400.0 .. 1000A

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

Type of electrical connection of main circuit

Bolt connection

DIN rail (top hat rail) mounting optional

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of poles

3

Number of auxiliary contacts as normally open contact

0

Type of control element

Toggle

With integrated under voltage release

Complete device with protection unit

Position of connection for main current circuit

Front side

Degree of protection (IP)

IP20

Motor drive integrated

Motor drive optional