Aleta.hr
Main Product Image

1SDA100909R1 | XT7H 1600 Ekip Touch LSIG In1600A 3p F F

Code: 1893758

ManufacturerABB
Catalog number1SDA100909R1
EAN code8056221009638

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release2400.0 - 24000A
Number of auxiliary contacts as normally open contact0
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Rated voltage220 - 690V
Integrated earth fault protectionYes
Overload release current setting640.0 - 1600A
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
With integrated under voltage releaseNo
Position of connection for main current circuitFront side
Type of control elementToggle
Motor drive optionalYes
Motor drive integratedNo
Complete device with protection unitYes
Number of poles3
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100909R1 | XT7H 1600 Ekip Touch LSIG In1600A 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Number of auxiliary contacts as normally open contact

0

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Rated voltage

220 .. 690V

Integrated earth fault protection

Overload release current setting

640.0 .. 1600A

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

With integrated under voltage release

Position of connection for main current circuit

Front side

Type of control element

Toggle

Motor drive optional

Motor drive integrated

Complete device with protection unit

Number of poles

3

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.