Aleta.hr
Main Product Image

1SDA100910R1 | XT7H 800 Ekip Touch Meas.LSI In800 3p FF

Code: 1893759

ManufacturerABB
Catalog number1SDA100910R1
EAN code8056221009645

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage220 - 690V
Rated permanent current Iu800A
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Overload release current setting320.0 - 800A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Number of poles3
Position of connection for main current circuitFront side
Complete device with protection unitYes
With integrated under voltage releaseNo
Motor drive optionalYes
Type of control elementToggle
Motor drive integratedNo
Number of auxiliary contacts as normally open contact0
Degree of protection (IP)IP20
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100910R1 | XT7H 800 Ekip Touch Meas.LSI In800 3p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

Rated permanent current Iu

800A

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Overload release current setting

320.0 .. 800A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Number of poles

3

Position of connection for main current circuit

Front side

Complete device with protection unit

With integrated under voltage release

Motor drive optional

Type of control element

Toggle

Motor drive integrated

Number of auxiliary contacts as normally open contact

0

Degree of protection (IP)

IP20

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.