Aleta.hr
Main Product Image

1SDA100913R1 | XT7H 1600 Ekip Touch Meas.LSI 1600 3p FF

Code: 1893762

ManufacturerABB
Catalog number1SDA100913R1
EAN code8056221009676

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Rated voltage220 - 690V
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Position of connection for main current circuitFront side
Motor drive integratedNo
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Number of poles3
Type of control elementToggle
Rated permanent current Iu1600A
DIN rail (top hat rail) mounting optionalYes
Overload release current setting640.0 - 1600A
Integrated earth fault protectionNo
Adjustment range undelayed short-circuit release2400.0 - 24000A
Motor drive optionalYes
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA100913R1 | XT7H 1600 Ekip Touch Meas.LSI 1600 3p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Rated voltage

220 .. 690V

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Position of connection for main current circuit

Front side

Motor drive integrated

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Number of poles

3

Type of control element

Toggle

Rated permanent current Iu

1600A

DIN rail (top hat rail) mounting optional

Overload release current setting

640.0 .. 1600A

Integrated earth fault protection

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Motor drive optional

With integrated under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.