Aleta.hr
Main Product Image

1SDA101121R1 | XT7S 1600 Ekip Dip LSI In=1600A 4p F F

Code: 1893956

ManufacturerABB
Catalog number1SDA101121R1
EAN code8056221014243

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuitBolt connection
Rated permanent current Iu1600A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Adjustment range undelayed short-circuit release1600 - 16000A
Adjustment range short-term delayed short-circuit release1600 - 16000A
Number of auxiliary contacts as normally closed contact0
Device constructionBuilt-in device fixed built-in technique
Number of poles4
With integrated under voltage releaseNo
With switched-off indicatorNo
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
Complete device with protection unitYes
Position of connection for main current circuitFront side
Overload release current setting640.0 - 1600A
DIN rail (top hat rail) mounting optionalYes
Motor drive integratedNo
Degree of protection (IP)IP20
Integrated earth fault protectionNo
Rated voltage220 - 690V
Type of control elementToggle
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101121R1 | XT7S 1600 Ekip Dip LSI In=1600A 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Rated permanent current Iu

1600A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Adjustment range undelayed short-circuit release

1600 .. 16000A

Adjustment range short-term delayed short-circuit release

1600 .. 16000A

Number of auxiliary contacts as normally closed contact

0

Device construction

Built-in device fixed built-in technique

Number of poles

4

With integrated under voltage release

With switched-off indicator

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

Complete device with protection unit

Position of connection for main current circuit

Front side

Overload release current setting

640.0 .. 1600A

DIN rail (top hat rail) mounting optional

Motor drive integrated

Degree of protection (IP)

IP20

Integrated earth fault protection

Rated voltage

220 .. 690V

Type of control element

Toggle

Motor drive optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.