Aleta.hr
Main Product Image

1SDA101134R1 | XT7S 800 Ekip Touch Meas.LSI In800 4p FF

Code: 1893969

ManufacturerABB
Catalog number1SDA101134R1
EAN code8056221014373

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu800A
Integrated earth fault protectionNo
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Overload release current setting320.0 - 800A
Rated voltage220 - 690V
Device constructionBuilt-in device fixed built-in technique
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1200.0 - 12000A
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
With integrated under voltage releaseNo
Number of poles4
Type of control elementToggle
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive integratedNo
Motor drive optionalYes
Degree of protection (IP)IP20
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101134R1 | XT7S 800 Ekip Touch Meas.LSI In800 4p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

800A

Integrated earth fault protection

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Overload release current setting

320.0 .. 800A

Rated voltage

220 .. 690V

Device construction

Built-in device fixed built-in technique

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

With integrated under voltage release

Number of poles

4

Type of control element

Toggle

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive integrated

Motor drive optional

Degree of protection (IP)

IP20

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.