Technical specifications

Rated permanent current Iu1000A
Rated voltage220 - 690V
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Type of electrical connection of main circuitBolt connection
Adjustment range undelayed short-circuit release1500.0 - 15000A
Device constructionBuilt-in device fixed built-in technique
Overload release current setting400.0 - 1000A
Number of poles4
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
With switched-off indicatorNo
Number of auxiliary contacts as normally open contact0
Integrated earth fault protectionNo
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Motor drive integratedNo
Complete device with protection unitYes
DIN rail (top hat rail) mounting optionalYes
Motor drive optionalYes
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Number of auxiliary contacts as normally closed contact0
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101183R1 | XT7H 1000 Ekip Touch LSI In=1000A 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1000A

Rated voltage

220 .. 690V

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Type of electrical connection of main circuit

Bolt connection

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Device construction

Built-in device fixed built-in technique

Overload release current setting

400.0 .. 1000A

Number of poles

4

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

With switched-off indicator

Number of auxiliary contacts as normally open contact

0

Integrated earth fault protection

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Motor drive integrated

Complete device with protection unit

DIN rail (top hat rail) mounting optional

Motor drive optional

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Number of auxiliary contacts as normally closed contact

0