Technical specifications

Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Rated permanent current Iu1600A
Overload release current setting640.0 - 1600A
Device constructionBuilt-in device fixed built-in technique
Adjustment range undelayed short-circuit release2400.0 - 24000A
Type of electrical connection of main circuitBolt connection
Integrated earth fault protectionNo
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
DIN rail (top hat rail) mounting optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as change-over contact0
Motor drive integratedNo
Number of poles4
Complete device with protection unitYes
Position of connection for main current circuitFront side
Motor drive optionalYes
Degree of protection (IP)IP20
Type of control elementToggle
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101185R1 | XT7H 1600 Ekip Touch LSI In=1600A 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Rated permanent current Iu

1600A

Overload release current setting

640.0 .. 1600A

Device construction

Built-in device fixed built-in technique

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Type of electrical connection of main circuit

Bolt connection

Integrated earth fault protection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as change-over contact

0

Motor drive integrated

Number of poles

4

Complete device with protection unit

Position of connection for main current circuit

Front side

Motor drive optional

Degree of protection (IP)

IP20

Type of control element

Toggle

With integrated under voltage release