Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of poles4
Rated voltage220 - 690V
Number of auxiliary contacts as change-over contact0
Rated permanent current Iu800A
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Overload release current setting320.0 - 800A
Position of connection for main current circuitFront side
Suitable for DIN rail (top hat rail) mountingNo
Type of control elementToggle
Motor drive integratedNo
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionYes
Adjustment range undelayed short-circuit release800 - 8000A
With switched-off indicatorNo
Type of electrical connection of main circuitBolt connection
Complete device with protection unitYes
Adjustment range short-term delayed short-circuit release800 - 8000A
Motor drive optionalYes
DIN rail (top hat rail) mounting optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101234R1 | XT7L 800 Ekip Dip LSIG In=800A 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of poles

4

Rated voltage

220 .. 690V

Number of auxiliary contacts as change-over contact

0

Rated permanent current Iu

800A

With integrated under voltage release

Degree of protection (IP)

IP20

Overload release current setting

320.0 .. 800A

Position of connection for main current circuit

Front side

Suitable for DIN rail (top hat rail) mounting

Type of control element

Toggle

Motor drive integrated

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Adjustment range undelayed short-circuit release

800 .. 8000A

With switched-off indicator

Type of electrical connection of main circuit

Bolt connection

Complete device with protection unit

Adjustment range short-term delayed short-circuit release

800 .. 8000A

Motor drive optional

DIN rail (top hat rail) mounting optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.