Technical specifications

Rated permanent current Iu800A
Adjustment range undelayed short-circuit release1200.0 - 12000A
Adjustment range short-term delayed short-circuit release480.0 - 8000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Rated voltage220 - 690V
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Overload release current setting320.0 - 800A
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
Complete device with protection unitYes
Number of auxiliary contacts as normally open contact0
Position of connection for main current circuitFront side
Number of auxiliary contacts as change-over contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of poles4
Degree of protection (IP)IP20
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Motor drive optionalYes
Motor drive integratedNo
With integrated under voltage releaseNo
Device constructionBuilt-in device fixed built-in technique
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101238R1 | XT7L 800 Ekip Touch LSI In=800A 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

800A

Adjustment range undelayed short-circuit release

1200.0 .. 12000A

Adjustment range short-term delayed short-circuit release

480.0 .. 8000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Rated voltage

220 .. 690V

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Overload release current setting

320.0 .. 800A

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Number of auxiliary contacts as normally open contact

0

Position of connection for main current circuit

Front side

Number of auxiliary contacts as change-over contact

0

Suitable for DIN rail (top hat rail) mounting

Number of poles

4

Degree of protection (IP)

IP20

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Motor drive optional

Motor drive integrated

With integrated under voltage release

Device construction

Built-in device fixed built-in technique

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.