Technical specifications

Rated permanent current Iu1600A
Overload release current setting640.0 - 1600A
Rated voltage220 - 690V
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Suitable for DIN rail (top hat rail) mountingNo
DIN rail (top hat rail) mounting optionalYes
Adjustment range undelayed short-circuit release2400.0 - 24000A
Device constructionBuilt-in device fixed built-in technique
Integrated earth fault protectionNo
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as change-over contact0
With switched-off indicatorNo
Number of auxiliary contacts as normally closed contact0
Motor drive optionalYes
With integrated under voltage releaseNo
Degree of protection (IP)IP20
Complete device with protection unitYes
Motor drive integratedNo
Number of poles4
Position of connection for main current circuitFront side
Type of control elementToggle
Number of auxiliary contacts as normally open contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101241R1 | XT7L 1600 Ekip Touch LSI In=1600A 4p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1600A

Overload release current setting

640.0 .. 1600A

Rated voltage

220 .. 690V

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Suitable for DIN rail (top hat rail) mounting

DIN rail (top hat rail) mounting optional

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Device construction

Built-in device fixed built-in technique

Integrated earth fault protection

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as change-over contact

0

With switched-off indicator

Number of auxiliary contacts as normally closed contact

0

Motor drive optional

With integrated under voltage release

Degree of protection (IP)

IP20

Complete device with protection unit

Motor drive integrated

Number of poles

4

Position of connection for main current circuit

Front side

Type of control element

Toggle

Number of auxiliary contacts as normally open contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA