Aleta.hr
Main Product Image

1SDA101372R1 | XT7S M 1250 Ekip Dip LSI In=1250A 3p F F

Code: 1894189

ManufacturerABB
Catalog number1SDA101372R1
EAN code8056221011907

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1250A
Device constructionBuilt-in device fixed built-in technique
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Overload release current setting500.0 - 1250A
DIN rail (top hat rail) mounting optionalYes
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Adjustment range undelayed short-circuit release1250 - 12500A
Adjustment range short-term delayed short-circuit release1250 - 12500A
Number of auxiliary contacts as change-over contact0
Type of control elementToggle
Position of connection for main current circuitFront side
Number of poles3
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz50kA
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Degree of protection (IP)IP20
With integrated under voltage releaseNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101372R1 | XT7S M 1250 Ekip Dip LSI In=1250A 3p F F

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1250A

Device construction

Built-in device fixed built-in technique

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Overload release current setting

500.0 .. 1250A

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Adjustment range undelayed short-circuit release

1250 .. 12500A

Adjustment range short-term delayed short-circuit release

1250 .. 12500A

Number of auxiliary contacts as change-over contact

0

Type of control element

Toggle

Position of connection for main current circuit

Front side

Number of poles

3

Complete device with protection unit

Motor drive integrated

Motor drive optional

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

50kA

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Degree of protection (IP)

IP20

With integrated under voltage release

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.