Technical specifications

Rated voltage220 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Adjustment range undelayed short-circuit release1500.0 - 15000A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionNo
Rated permanent current Iu1000A
Adjustment range short-term delayed short-circuit release600.0 - 10000A
Device constructionBuilt-in device fixed built-in technique
DIN rail (top hat rail) mounting optionalYes
Overload release current setting400.0 - 1000A
Type of electrical connection of main circuitBolt connection
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as normally open contact0
Number of poles3
Motor drive integratedNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Type of control elementToggle
With integrated under voltage releaseNo
Motor drive optionalYes
Degree of protection (IP)IP20
Number of auxiliary contacts as change-over contact0
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101507R1 | XT7L M 1000 Ekip Touch LSI In1000A 3p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated voltage

220 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Adjustment range undelayed short-circuit release

1500.0 .. 15000A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

Rated permanent current Iu

1000A

Adjustment range short-term delayed short-circuit release

600.0 .. 10000A

Device construction

Built-in device fixed built-in technique

DIN rail (top hat rail) mounting optional

Overload release current setting

400.0 .. 1000A

Type of electrical connection of main circuit

Bolt connection

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as normally open contact

0

Number of poles

3

Motor drive integrated

With switched-off indicator

Position of connection for main current circuit

Front side

Type of control element

Toggle

With integrated under voltage release

Motor drive optional

Degree of protection (IP)

IP20

Number of auxiliary contacts as change-over contact

0

Complete device with protection unit

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.