Aleta.hr
Main Product Image

1SDA101545R1 | XT7L M 1600 Ekip G Touch LSIG 1600 3p FF

Code: 1894354

ManufacturerABB
Catalog number1SDA101545R1
EAN code8056221015899

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1600A
Rated voltage220 - 690V
Number of auxiliary contacts as normally closed contact0
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Suitable for DIN rail (top hat rail) mountingNo
Integrated earth fault protectionYes
With integrated under voltage releaseNo
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Complete device with protection unitYes
Overload release current setting640.0 - 1600A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as change-over contact0
Number of auxiliary contacts as normally open contact0
With switched-off indicatorNo
Motor drive integratedNo
Number of poles3
Adjustment range undelayed short-circuit release2400.0 - 24000A
Motor drive optionalYes
Degree of protection (IP)IP20
Position of connection for main current circuitFront side
Type of control elementToggle
DIN rail (top hat rail) mounting optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101545R1 | XT7L M 1600 Ekip G Touch LSIG 1600 3p FF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1600A

Rated voltage

220 .. 690V

Number of auxiliary contacts as normally closed contact

0

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Suitable for DIN rail (top hat rail) mounting

Integrated earth fault protection

With integrated under voltage release

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Complete device with protection unit

Overload release current setting

640.0 .. 1600A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Number of auxiliary contacts as normally open contact

0

With switched-off indicator

Motor drive integrated

Number of poles

3

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Motor drive optional

Degree of protection (IP)

IP20

Position of connection for main current circuit

Front side

Type of control element

Toggle

DIN rail (top hat rail) mounting optional

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.