Aleta.hr
Main Product Image

1SDA101732R1 | XT7H M 1250 EkipTouch Meas.LSI 1250 4pFF

Code: 1894527

ManufacturerABB
Catalog number1SDA101732R1
EAN code8056221017763

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu1250A
Rated voltage220 - 690V
Overload release current setting500.0 - 1250A
Adjustment range short-term delayed short-circuit release750.0 - 12500A
Adjustment range undelayed short-circuit release1875.0 - 18750A
Type of electrical connection of main circuitBolt connection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz70kA
Integrated earth fault protectionNo
Device constructionBuilt-in device fixed built-in technique
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as normally closed contact0
Number of auxiliary contacts as change-over contact0
DIN rail (top hat rail) mounting optionalYes
Number of poles4
Position of connection for main current circuitFront side
Complete device with protection unitYes
Motor drive integratedNo
Motor drive optionalYes
Type of control elementToggle
Degree of protection (IP)IP20
With integrated under voltage releaseNo
With switched-off indicatorNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101732R1 | XT7H M 1250 EkipTouch Meas.LSI 1250 4pFF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Rated permanent current Iu

1250A

Rated voltage

220 .. 690V

Overload release current setting

500.0 .. 1250A

Adjustment range short-term delayed short-circuit release

750.0 .. 12500A

Adjustment range undelayed short-circuit release

1875.0 .. 18750A

Type of electrical connection of main circuit

Bolt connection

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

70kA

Integrated earth fault protection

Device construction

Built-in device fixed built-in technique

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Number of auxiliary contacts as change-over contact

0

DIN rail (top hat rail) mounting optional

Number of poles

4

Position of connection for main current circuit

Front side

Complete device with protection unit

Motor drive integrated

Motor drive optional

Type of control element

Toggle

Degree of protection (IP)

IP20

With integrated under voltage release

With switched-off indicator

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.