Technical specifications

Type of electrical connection of main circuitBolt connection
Adjustment range short-term delayed short-circuit release960.0 - 16000A
Adjustment range undelayed short-circuit release2400.0 - 24000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Number of auxiliary contacts as change-over contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
With switched-off indicatorNo
Rated permanent current Iu1600A
Device constructionBuilt-in device fixed built-in technique
Number of auxiliary contacts as normally open contact0
DIN rail (top hat rail) mounting optionalYes
Overload release current setting640.0 - 1600A
Type of control elementToggle
Complete device with protection unitYes
Number of poles4
Degree of protection (IP)IP20
Motor drive optionalYes
Motor drive integratedNo
Rated voltage220 - 690V
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitFront side
Integrated earth fault protectionYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101793R1 | XT7L M 1600 EkipTouchMeas.LSIG 1600 4pFF

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Type of electrical connection of main circuit

Bolt connection

Adjustment range short-term delayed short-circuit release

960.0 .. 16000A

Adjustment range undelayed short-circuit release

2400.0 .. 24000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Number of auxiliary contacts as change-over contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

With switched-off indicator

Rated permanent current Iu

1600A

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as normally open contact

0

DIN rail (top hat rail) mounting optional

Overload release current setting

640.0 .. 1600A

Type of control element

Toggle

Complete device with protection unit

Number of poles

4

Degree of protection (IP)

IP20

Motor drive optional

Motor drive integrated

Rated voltage

220 .. 690V

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Front side

Integrated earth fault protection