Technical specifications

Number of auxiliary contacts as normally open contact0
Number of poles4
Number of auxiliary contacts as normally closed contact0
Overload release current setting320.0 - 800A
Number of auxiliary contacts as change-over contact0
Rated voltage220 - 690V
With integrated under voltage releaseNo
Type of control elementToggle
Type of electrical connection of main circuitBolt connection
Degree of protection (IP)IP20
Motor drive integratedNo
With switched-off indicatorNo
Position of connection for main current circuitFront side
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz120kA
Adjustment range undelayed short-circuit release800 - 8000A
Motor drive optionalYes
Suitable for DIN rail (top hat rail) mountingNo
Complete device with protection unitYes
Device constructionBuilt-in device fixed built-in technique
Rated permanent current Iu800A
DIN rail (top hat rail) mounting optionalYes
Adjustment range short-term delayed short-circuit release- - -A
Integrated earth fault protectionNo
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA101818R1 | XT7L M 800 Ekip Dip LIG In=800A 4p F F

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

Number of poles

4

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

320.0 .. 800A

Number of auxiliary contacts as change-over contact

0

Rated voltage

220 .. 690V

With integrated under voltage release

Type of control element

Toggle

Type of electrical connection of main circuit

Bolt connection

Degree of protection (IP)

IP20

Motor drive integrated

With switched-off indicator

Position of connection for main current circuit

Front side

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

120kA

Adjustment range undelayed short-circuit release

800 .. 8000A

Motor drive optional

Suitable for DIN rail (top hat rail) mounting

Complete device with protection unit

Device construction

Built-in device fixed built-in technique

Rated permanent current Iu

800A

DIN rail (top hat rail) mounting optional

Adjustment range short-term delayed short-circuit release

- .. -A

Integrated earth fault protection